FANUC SERVO ALARMS
Fanuc Servo Alarms (list by Fanuc ALPHA servo amplifier type). If you require earlier NON alpha modules and units click here. The servo drive alarms listed on this page are for alpha numeric digits on the single seven segment LED display present on all of these ALPHA servo modules and units. Below is the meaning of the various FANUC servo amplifier alarms. Contact us for more information.
Type A & Type B, FSSB (A06B-6079, 6080, 6096, 6097-Hxxx)
- 1 = Fan alarm
- 2 = Low Voltage (Control 5V)
- 5 = DC Link under voltage
- 8 = HCL (high current L axis)
- 8. = IPM L axis
- 9 = HCM (high current M axis)
- 9. = IPM M axis
- A = Over-current (N axis)
- A. = IPM N axis
- b = HC (high current L/M/N axis)
- F = Cooling fan stopped
- U = COP10B comm error FSSB
- L = COP10A comm error FSSB
ALPHA i aiSV amplifiers (A06B-6114. 6117, 6124, 6127-Hxxx)
- 1 = Fan alarm
- 2 = Low voltage
- 5 = DC Link
- F = Cooling Fan
- 8, 9, A = Overcurrent (N axis)
- 8., 9., A. = IPM alarm on corresponding axis axis
- b, c, d = HC (high current L &/or M &/or N axis)
SVU servo amplifier units (A06B-6089-Hxxx & A06B-6090-Hxxx)
1 | Over Voltage alarm ( HV) |
2 | Low control power voltage alarm (LV) |
3 | Low DC voltage alarm (LVDC) |
5 | Over regenerative discharge alarm (DCOH) |
8 | L-axis over current alarm (HCL) |
9 | M-axis over current alarm (HCM) |
6 | L and M axis over current alarm (HCM) |
8. | L-axis IPM alarm ( IPML) |
9. | M-axis IPM alarm (IPMM) |
b | L and M axis IPM alarm |
The ALPHA SVU drives such as the 6089 and 6090 series of self powered amplifiers; are now the BETA i series of units. Such as the 6136, etc.